[Automotive Oscilloscope Starter Kit] PicoScope 2204A Full Kit 2 channel 10MHz, 8-bit Oscilloscope
Features:
- 2 channels
- 10 MHz bandwidth
- With Probes
- Up to 1 GS/s sampling rate
- Arbitrary waveform generator
- Advanced digital triggers
- Persistence display modes
- USB connected and powered
- Mask limit testing
- Serial bus decoding
Specifications:
PicoScope 2200A Series Specifications | |||||
Oscilloscope – Vertical | |||||
Model | PicoScope 2204A | PicoScope 2205A | PicoScope 2206A | PicoScope 2207A | PicoScope 2208A |
Input channels | 2 | ||||
Bandwidth | 10 MHz | 25 MHz | 50 MHz | 100 MHz | 200 MHz |
Rise time (calculated) | 35 ns | 14 ns | 7 ns | 3.5 ns | 1.75 ns |
Input type | BNC | ||||
Vertical resolution | 8 bits | ||||
Enhanced vertical resolution | Up to 12 bits | ||||
Input sensitivity | 10 mV/div to 4 V/div (10 vertical divisions) | ||||
Input ranges | ±50 mV, ±100 mV, ±200 mV, ±500 mV, ±1 V, ±2 V, ±5 V, ±10 V, ±20 V | ||||
Input coupling | Software selectable AC/DC | ||||
Input characteristics | BNC, 1 MΩ ∥ 14 pF | BNC, 1 MΩ ∥ 13 pF | |||
DC accuracy | ±3% of full scale | ||||
Analog offset range (vertical position adjust) |
none | ±250 mV (50 mV to 200 mV ranges) ±2.5 V (500 mV to 2 V ranges) ±20 V (5 V to 20 V ranges) |
|||
Overvoltage protection | ±100 V (DC + AC peak) | ||||
Oscilloscope – Horizontal | |||||
Maximum sampling rate (real-time) 1 channel 2 channel |
100 MS/s 50 MS/s |
200 MS/s 100 MS/s |
500 MS/s 250 MS/s |
1 GS/s 500 MS/s |
1 GS/s 500 MS/s |
Maximum sampling rate (repetitive signals, ETS mode) | 2 GS/s | 4 GS/s | 5 GS/s | 10 GS/s | 10 GS/s |
Maximum sampling rate (continuous streaming mode) | 1 MS/s | 9.6 MS/s | |||
Maximum waveforms per second | 2200 | 3300 | 5700 | 6300 | 8500 |
Timebase ranges | 10 ns to 5000 s/div | 5 ns to 5000 s/div | 2 ns to 5000 s/div | 1 ns to 5000 s/div | 500 ps to 5000 s/div |
Buffer memory# | 8 kS | 16 kS | 32 kS | 40 kS | 48 kS |
Buffer memory (streaming mode) | 2 MS per channel in PicoScope software. | 100 MS (shared) in PicoScope software. | |||
Waveform buffer normal triggering rapid block triggering |
Up to 10,000 waveforms not applicable |
Up to 10,000 waveforms Up to 32 waveforms |
|||
Timebase accuracy | ±100 ppm | ±50 ppm | |||
Sample jitter | < 30 ps RMS | < 5 ps RMS | |||
Spectrum analyzer | |||||
Frequency range | DC to 10 MHz | DC to 25 MHz | DC to 50 MHz | DC to 100 MHz | DC to 200 MHz |
Display modes | Magnitude, peak hold, average | ||||
Window types | Rectangular, Gaussian, triangular, Blackman, Blackman–Harris, Hamming, Hann, flat–top | ||||
Number of FFT points | Selectable from 128 to half the available buffer memory in powers of 2 | ||||
Scale / units | X axis : linear or log 10 Y axis : logarithmic (dbV, dBu, dBm, arbitrary) or linear (volts) |
* Buffer memory is shared between active channels.
Dynamic performance (typical) | ||
Crosstalk (full bandwidth) | Better than 200:1 (equal ranges) | Better than 400:1 (equal ranges) |
Harmonic distortion | < -50 dB at 100 kHz, full–scale input | |
SFDR | > 52 dB at 100 kHz, full–scale input | |
Noise | < 150 μV RMS (±50 mV range) | < 200 μV RMS (±50 mV range) |
Bandwidth flatness (at scope input) | (+0.3 dB, -3 dB) from DC to full bandwidth | |
Triggering | ||
Sources | Ch A, Ch B | |
Trigger modes | None, auto, repeat, single | None, auto, repeat, single, rapid (segmented memory) |
Advanced triggers | Edge, window, pulse width, window pulse width, dropout, window dropout, interval, logic. | |
Trigger types, ETS | Rising or falling edge | |
Trigger level | Adjustable over whole of selected voltage range | |
Trigger sensitivity | Digital triggering provides 1 LSB accuracy up to full bandwidth. In ETS mode, typical 10 mV p-p at full bandwidth | |
Maximum pre-trigger capture | 100% of capture size | |
Maximum post-trigger delay | 4 billion samples | |
Trigger rearm time | PC-dependent | < 2 µs on fastest timebase |
Maximum trigger rate | PC-dependent | Up to 32 waveforms in a 64 μs burst |
Function generator | ||
Standard output signals | Sine, square, triangle, DC voltage, ramp, sinc, Gaussian, half-sine | |
Pseudorandom output signals | None | White noise, PRBS |
Standard signal frequency | DC to 100 kHz | DC to 1 MHz |
Sweep modes | Up, down, dual with selectable start/stop frequencies and increments | |
Output frequency accuracy | ±100 ppm | ±50 ppm |
Output frequency resolution | < 0.01 Hz | |
Output voltage range | ±2 V | |
Output adjustments | Any amplitude and offset within ±2 V range | |
Amplitude flatness (typical) | < 1 dB to 100 kHz | < 0.5 dB to 1 MHz |
DC accuracy | ±1% of full scale | |
SFDR | > 55 dB @ 1 kHz full–scale sine wave | > 60 dB @ 10 kHz full–scale sine wave |
Connector type | Front panel BNC with 600 Ω output impedance | |
Overvoltage protection | ±10 V | |
Arbitrary waveform generator | ||
Update rate | 2 MS/s | 20 MS/s |
Buffer size | 4 kS | 8 kS |
Resolution | 12 bits | |
Bandwidth | >100 kHz | >1 MHz |
Rise time (10% to 90%) | < 2 µs | < 120 ns |
Math channels | |
Functions | −x, x+y, x−y, x*y, x/y, x^y, sqrt, exp, ln, log, abs, norm, sign, sin, cos, tan, arcsin, arccos, arctan, sinh, cosh, tanh, freq, derivative, integral, min, max, average, peak, delay |
Operands | A, B (input channels), T (time), reference waveforms, constants, Pi |
Automatic measurements | |
Oscilloscope mode | AC RMS, true RMS, cycle time, DC average, duty cycle, falling rate, fall time, frequency, high pulse width, low pulse width, maximum, minimum, peak to peak, rise time, rising rate. |
Spectrum mode | Frequency at peak, amplitude at peak, average amplitude at peak, total power, THD %, THD dB, THD plus noise, SFDR, SINAD, SNR, IMD |
Statistics | Minimum, maximum, average and standard deviation |
Serial decoding | |
Protocols | CAN, LIN, I²C, UART/RS-232, SPI, I²S, FlexRay |
Inputs | All input channels with any mixture of protocols |
Mask limit testing | |
Mask generation | Auto generate from captured waveform, manual drawing, manual coordinate entry |
Actions | Highlight on screen, select in buffer overview, activate alarm |
Statistics | Pass/fail, failure count, total count |
Alarms | |
Initiating events | Capture, buffer full, mask fail |
Alarm actions | Beep, play sound, stop/restart capture, run executable, save current buffer/all buffers, trigger signal generator |
Display | |
Interpolation | Linear or sin(x)/x |
Persistence modes | Digital color, analog intensity, fast, custom |
Data export | |
Output file formats | BMP, CSV, GIF, JPG, MATLAB 4, PDF, PNG, PicoScope data, PicoScope settings, TXT |
Output functions | Copy to clipboard, print |
Environmental | |
Temperature range (operating) | 0 °C to 50 °C |
Temperature range (stated accuracy) | 20 °C to 30 °C |
Temperature range (storage) | –20 °C to +60 °C |
Humidity range (operating) | 5% to 80% RH non-condensing |
Humidity range (storage) | 5% to 95% RH non-condensing |
Physical properties | |
Dimensions (including connectors) | 142 x 92 x 19 mm |
Weight | < 0.2 kg (7 oz) |
Software | |
Software included | PicoScope 6 for Windows oscilloscope software (all models) PicoLog for Windows data logging software (PicoScope 2204A and 2205A only) |
Optional free software | PicoScope 6 Beta for Linux and OS X. Drivers for Linux and OS X. |
Languages | Chinese (simplified), Chinese (traditional), Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Romanian, Russian, Spanish, Swedish, Turkish |
General | |
Additional hardware supplied | Quick start guide, software CD–ROM |
PC requirements | Microsoft Windows XP (SP3), Vista, Windows 7 or Windows 8 (not Windows RT). |
PC connectivity | USB 2.0 port (compatible with USB 1.1 and USB 3.0; USB 1.1 not recommended) |
Power requirements | Powered from USB port |
Safety approvals | Designed to EN 61010-1:2010 |
Compliance | RoHS, WEEE, and LVD compliant. Tested to meet EN61326-1:2006 and FCC Part 15 Subpart B. |
Total satisfaction guarantee | In the event that this product does not fully meet your requirements you can return it for an exchange or refund. To claim, the product must be returned in good condition within 14 days. |
Warranty | 1 year |
Package List:
1x PicoScope 2204A Main Unit
2x Probe
1x USB Cable
1x Hantek CC65
1x Hantek CC650
2x Hantek PP80 Probe
2x Hantek HT311 BNC to Banana Adapter
2x Hantek HT201 20:1 Attenuator
2x Hantek HT25 Auto Ignition Probe
2x Hantek HT308 Coil Probe
5x Hantek HT307 Needle Back Test Probe
2x Hantek HT30A Scope Leads
4x Hantek HT18A Crocodile Clip