PicoScope 2 Channel Oscilloscopes Specifications:
Model PicoScope
2204A
PicoScope
2205A
PicoScope
2206B
PicoScope
2207B
PicoScope
2208B
VERTICAL
Input channels 2
Bandwidth 10 MHz 25 MHz 50 MHz 70 MHz 100 MHz
Rise time (calculated) 35 ns 14 ns 7 ns 5 ns 3.5 ns
Input type BNC(f)
Vertical resolution 8 bits
Enhanced vertical resolution Up to 12 bits
Input sensitivity 4 mV/div to 4 V/div (10 vertical divisions)
Input ranges ±50 mV, ±100 mV, ±200 mV, ±500 mV,  ±1 V, ±2 V, ±5 V, ±10 V, ±20 V ±20 mV, ±50 mV, ±100 mV, ±200 mV, ±500 mV, ±1 V, ±2 V, ±5 V, ±10 V, ±20 V
Input coupling AC/DC
Input characteristics 1 MΩ ± 1% ∥ 14 pF ± 2 pF 1 MΩ ± 1% ∥ 16 pF ± 1 pF
DC accuracy ±3% of full scale ±200 μV
Analog offset range
(vertical position adjust)
none ±250 mV (50 mV to 200 mV ranges)
±2.5 V (500 mV to 2 V ranges)
±20 V (5 V to 20 V ranges)
Overvoltage protection ±100 V (DC + AC peak)
HORIZONTAL (TIMEBASE)
Maximum sampling rate (real-time)
1 channel
2 channel
100 MS/s
50 MS/s
200 MS/s
100 MS/s
100 MS/s
500 MS/s
250 MS/s
1 GS/s
500 MS/s
1 GS/s
500 MS/s
Maximum sampling rate (repetitive signals, ETS mode) 2 GS/s 4 GS/s 5 GS/s 10 GS/s 10 GS/s
Maximum sampling rate (continuous streaming mode) 1 MS/s 9.6 MS/s (31 MS/s with SDK)
Shortest timebase 10 ns/div 5 ns/div 2 ns/div 1 ns/div 1 ns/div
Longest timebase 5000 s/div 5000 s/div 5000 s/div 5000 s/div 5000 s/div
Buffer memory (block mode, shared  between active channels) 8 kS 16 kS 32 MS 64 MS 128 MS
Buffer memory (streaming mode, SDK) Up to available PC memory 128 000 256 000 500 000
Buffers (SDK) 1 128 000 256 000 500 000
Buffers (PicoScope software) 10 000 10 000
Timebase accuracy ±100 ppm ±50 ppm
Sample jitter 20 ps RMS typical 20 ps RMS typical 3 ps RMS typical
DYNAMIC PERFORMANCE (typical)
Crosstalk (full bandwidth) Better than 200:1 (equal ranges) Better than 400:1 (equal ranges)
Harmonic distortion < -50 dB at 100 kHz, full–scale input
SFDR (100 kHz, full-scale input, typical) > 52 dB ±20 mV range: > 44 dB
±50 mV range and higher: > 52 dB
Noise < 150 μV RMS (±50 mV range) < 200 μV RMS (±50 mV range) < 300 µV RMS  (±20 mV range)
Bandwidth flatness (at scope input) (+0.3 dB, -3 dB) from DC to full bandwidth
TRIGGERING
Sources Ch A, Ch B
Trigger modes None, auto, repeat, single None, auto, repeat, single, rapid (segmented memory)/td>
Advanced triggers Edge, window, pulse width, window pulse  width, dropout, window dropout, interval,  logic Edge, window, pulse width, window pulse width, dropout, window dropout, interval, runt pulse, logic
Trigger types, ETS Rising or falling edge Rising or falling edge (available on Ch A only)
Trigger sensitivity, real-time Digital triggering provides 1 LSB accuracy up to full bandwidth Digital triggering provides 1 LSB accuracy up to full bandwidth
Trigger sensitivity, ETS 10 mV p-p, typical, at full bandwidth 10 mV p-p, typical, at full bandwidth
Maximum pre-trigger capture 100% of capture size
Maximum post-trigger delay 4 billion samples
Trigger rearm time PC-dependent < 2 μs on fastest timebase < 1 µs on fastest timebase
Maximum trigger rate PC-dependent 10 000 waveforms in a 12 ms burst typical 10 000 waveforms in a 6 ms burst typical
Function generator
Standard output signals Sine, square, triangle, DC voltage, ramp, sinc, Gaussian, half-sine
Pseudorandom output signals None White noise, PRBS
Standard signal frequency DC to 100 kHz DC to 1 MHz
Sweep modes Up, down, dual with selectable start/stop frequencies and increments
Triggering None Free-run or up to 1 billion waveform cycles or frequency sweeps. Triggered from scope trigger or manually.
Output frequency accuracy Oscilloscope timebase accuracy ±  output frequency resolution
Output frequency resolution < 0.02 Hz < 0.01 Hz
Output voltage range ±2 V
Output adjustments Any amplitude and offset within ±2 V range
Amplitude flatness (typical) < 1 dB to 100 kHz < 0.5 dB to 1 MHz
DC accuracy ±1% of full scale
SFDR > 55 dB @ 1 kHz full–scale sine wave > 60 dB @ 10 kHz full–scale sine wave
Connector type Front panel BNC with 600 Ω output impedance
Overvoltage protection ±10 V ±20 V
ARBITRARY WAVEFORM GENERATOR
Update rate 1.548 MHz 20 MHz
Buffer size 4 kS 8 kS 32 kS
Resolution 8 bits 12 bits
Bandwidth >100 kHz >1 MHz
Rise time (10% to 90%) < 2 µs < 120 ns
SPECTRUM ANALYZER
Frequency range DC to analog bandwidth of oscilloscope
Display modes Magnitude, average, peak hold
Windowing functions Rectangular, Gaussian, triangular, Blackman, Blackman-Harris, Hamming, Hann, flat-top
Number of FFT points Selectable from 128 to half available buffer memory in powers of 2, up to a maximum of 1 048 576 points
MATH CHANNELS
Functions −x, x+y, x−y, x*y, x/y, x^y, sqrt, exp, ln, log, abs, norm, sign, sin, cos, tan, arcsin, arccos, arctan, sinh, cosh, tanh, freq, derivative, integral, min, max, average, peak, delay, duty, highpass, owpass, bandpass, bandstop
Operands A, B (input channels), C, D (input channels, 4-channel models only), T (time), reference waveforms, constants, pi, digital channels (MSO models only)
AUTOMATIC MEASUREMENTS
Scope mode AC RMS, true RMS, frequency, cycle time, duty cycle, DC average, falling rate, rising rate, low pulse width, high pulse width, fall time, rise time, minimum, maximum, peak to peak
Spectrum mode Frequency at peak, amplitude at peak, THD dB, SNR, SINAD, SFDR, total power, average amplitude at peak, THD %, THD+N, IMD,
Statistics Minimum, maximum, average and standard deviation
SERIAL DECODING
Protocols 1-Wire, ARINC 429, CAN, DCC, DMX512, FlexRay, Ethernet 10Base-T, USB 1.1, I²C, I²S, LIN, PS/2, SPI, SENT, UART/RS-232 (subject to bandwidth and sampling rate of chosen oscilloscope model) MASK LIMIT TESTING
Statistics Pass/fail, failure count, total count
DISPLAY
Interpolation Linear or sin(x)/x
Persistence modes Digital color, analog intensity, custom, fast or none
GENERAL
PC connectivity USB 2.0 (USB 3.0 compatible). USB cable included.
Power requirements Powered from USB port
Dimensions (including connectors and feet) 142 x 92 x 18.8 mm (PicoScope 2204A and 2205A only)
130 x 104 x 18.8 mm (all other models, including PicoScope 2205A MSO)
Weight < 0.2 kg (7 oz)
Temperature range, operating Operating: 0 °C to 50 °C
Temperature range, operating, for stated accuracy 15 °C to 30 °C
Temperature range, storage –20 °C to +60 °C
Humidity range, operating 5% to 80% RH non-condensing
Humidity range, storage 5% to 95% RH non-condensing
Altitude range up to 2000 m
Pollution degree 2
Safety approvals Designed to EN 61010-1:2010
Environmental approvals RoHS, WEEE
EMC approvals Tested to meet EN61326-1:2013 and FCC Part 15 Subpart B
Software included PicoScope 6 for Microsoft Windows 7, 8 (not Windows RT) and 10; 32-bit and 64-bit
SDK for Windows 7, 8 (not Windows RT) and 10; 32-bit and 64-bit
Example programs (C, Microsoft Excel VBA, LabVIEW)
Free software available for download PicoScope 6 (beta) for Linux and OS X
SDK (beta) for Linux and OS X
Languages supported Simplified Chinese, Czech, Danish, Dutch, English, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Romanian, Russian, Spanish, Swedish, Turkish

 

 

Package List:

1x PicoScope 2208B Main Unit
2x Probe
1x USB Cable

1x Hantek CC65
1x Hantek CC650
2x Hantek PP80 Probe
2x Hantek HT311 BNC to Banana Adapter
2x Hantek HT201 20:1 Attenuator
2x Hantek HT25 Auto Ignition Probe
2x Hantek HT308 Coil Probe
5x Hantek HT307 Needle Back Test Probe
2x Hantek HT30A Scope Leads
4x Hantek HT18A Crocodile Clip


We Also Recommend

Sale

Unavailable

Sold Out